Description / Abstract:
This method of test covers the specimen fabrication, testing protocols, and laboratory-accelerated weathering of detectable warning systems for the purposes of evaluating durability. This method of test covers the following categories:
Non-Destructive Evaluation Tests:
• Visual and Microscopic Evaluation (Section 6)
• Dome Shape and Geometry Measurement (Section 7)
• Static Coefficient of Friction Measurement, Dry and Wet (Section 8)
• Color Measurement (Section 9)
Destructive Evaluation Tests:
• Resistance to Impact from Falling Tup (Section 10)
• Resistant to Impact from Simulated Snowplow Blade (Cold Exposure) (Section 11)
• Wear Resistance (Section 12)
• Coating and Single Dome Bond (Systems with Coatings or Surface-Applied Single Domes) (Section 13)
Laboratory-Accelerated Weathering—Exposure Regime (Hot and Cold Exposure Categories):